Alpha and quantum yield of aquatic plants derived from PAM fluorometry: uses and misuses
Saroussi, S.; Beer, S. (2007). Alpha and quantum yield of aquatic plants derived from PAM fluorometry: uses and misuses. Aquat. Bot. 86(1): 89-92. http://dx.doi.org/10.1016/j.aquabot.2006.09.003
In: Aquatic Botany. Elsevier Science: Tokyo; Oxford; New York; London; Amsterdam. ISSN 0304-3770; e-ISSN 1879-1522, more
Peer reviewed article  

Available in  Authors 

Keywords
    Ulva Linnaeus, 1753 [WoRMS]
    Marine/Coastal
Author keywords
    alpha; initial slope; PAM fluorometry; P-I curve; quantum yield; rapidlight curve; Ulva sp.

Authors  Top 
  • Saroussi, S.
  • Beer, S.

Abstract
    The slope of the initial linear range of a photosynthesis–irradiance (PI) curve, alpha (a), is frequently, but often incorrectly, used to denote the maximal quantum yield (or the “efficiency” of photosynthesis) of higher plants and macroalgae under the conditions for which the PI curve was measured. When using the increasingly popular method of pulse amplitude modulated (PAM) fluorometry, the determination of a from so-called rapid light curves (RLC) may lead to misinterpretations when comparing photosynthetic efficiencies under different environmental conditions. Furthermore, since PAM fluorometry measures the quantum yield (Y) directly, there may be no need to estimate it from the initial slopes of RLCs.

    We compared photosynthetic parameters derived from RLCs of Ulva sp. measured during winter and summer, and show large differences in a when electron transport rates (ETR) were plotted against incident irradiance (Ii) [a = 0.26 ± 0.00 versus 0.08 ± 0.01 during the winter (November–December) and summer (July–August), respectively], as is usually done. On the other hand, no differences in the initial slopes of the RLCs were apparent when plotting ETR versus the absorbed irradiance (Ia) (initial slope = 0.75 ± 0.01 versus 0.62 ± 0.12 during the winter and summer, respectively); this is called for since also ETR is calculated using Ia. Using the Ia based RLCs, it was also found that the values of the initial slopes equalled those of the first Y-value measurements of the RLCs (Y0) (t-test, p > 0.05, r2 = 0.85). Therefore, when using PAM fluorometry, we suggest (a) to present the x-axis of RLCs as Ia (Ii × AF × 0.5), and ETR on the y-axis as Y × Ia, and (b) that Y0 can be taken as a correct measure of the maximal quantum yield instead of estimating it from an RLC.