IMIS | Vlaams Instituut voor de Zee
 

Vlaams Instituut voor de Zee

Platform voor marien onderzoek

IMIS

Publicaties | Instituten | Personen | Datasets | Projecten | Kaarten
[ meld een fout in dit record ]mandje (0): toevoegen | toon Print-vriendelijke versie

Three-Dimensional Reconstruction of the Tissue-Specific Multielemental Distribution withinCeriodaphnia dubiavia Multimodal Registration Using Laser Ablation ICP-Mass Spectrometry and X-ray Spectroscopic Techniques
Van Malderen, S.J.M.; Laforce, B.; Van Acker, T.; Nys, C.; De Rijcke, M.; de Rycke, R.; De Bruyne, M.; Boone, M.N.; De Schamphelaere, K.; Borovinskaya, O.; De Samber, B.; Vincze, L.; Vanhaecke, F. (2017). Three-Dimensional Reconstruction of the Tissue-Specific Multielemental Distribution withinCeriodaphnia dubiavia Multimodal Registration Using Laser Ablation ICP-Mass Spectrometry and X-ray Spectroscopic Techniques. Anal. Chem. 89(7): 4161-4168. https://hdl.handle.net/10.1021/acs.analchem.7b00111
In: Analytical chemistry. American Chemical Society: Washington. ISSN 0003-2700, meer
Peer reviewed article  

Beschikbaar in  Auteurs 

Trefwoord
    Zoet water

Auteurs  Top 
  • Van Malderen, S.J.M., meer
  • Laforce, B., meer
  • Van Acker, T.
  • Nys, C.
  • De Rijcke, M., meer
  • de Rycke, R.
  • De Bruyne, M.
  • Boone, M.N., meer
  • De Schamphelaere, K., meer
  • Borovinskaya, O.
  • De Samber, B., meer
  • Vincze, L., meer
  • Vanhaecke, F., meer

Abstract
    In this work, the three-dimensional elemental, distribution profile within the freshwater crustacean Ceriodaphnia dubia was constructed at a spatial resolution down to S mu m via a data, fusion approach employing state-of-the-art laser ablation inductively coupled plasma-time-of-flight mass spectrometry (LAICP-TOFMS) and laboratory-based absorption microcomputed tomography (mu-CT). C. dubia was exposed to elevated Cu, Ni, and Zn concentrations, chemically fixed, dehydrated, stained, and embedded, prior to mu-CT analysis. Subsequently, the sample was cut into 5 pm thin sections that were subjected to LA-ICPTOFMS imaging. Multimodal image registration was performed to spatially align the 2D LA-ICP-TOFMS images relative to the Corresponding slices of the 3D mu-CT reconstruction. Mass channels corresponding to the isotopes of a single element were merged to improve the signal-to-noise ratios within the elemental images. In order to aid the visual interpretation of the data, LA-ICP-TOEMS data wete projected onto the mu-CT voxels representing tissue. Additionally, the image resolution and elemental sensitivity were compared to those obtained with synchrotron radiation based 3D confocal mu-X-ray fluorescence imaging upon a chemically fixed and air-dried C. dubia specimen.

Alle informatie in IMIS valt onder het VLIZ Privacy beleid Top | Auteurs