VLIZ
VLAAMS INSTITUUT VOOR DE ZEE
MARIEN EN KUSTGEBONDEN ONDERZOEK & BELEID IN VLAANDEREN
   
© VLIZ © VLIZ © VLIZ © VLIZ © VLIZ
 
 
  English  Sitemap  Print
U bent hier: VLIZ > datacentrum
menu1 Over het VLIZ menu2 Infoloket menu3 Zeebibliotheek menu4 Cijfers&Beleid menu5 Faciliteiten menu6 Datacentrum
   
Datacentrum
  - IMIS: Integrated Marine Information System -
log in

Personen | Instituten | Publicaties | Projecten | Datasets | Kaarten
meld een fout in dit recordmandje (0): toevoegen | tonen Print-vriendelijke versie

Advances in the gas chromatographic determination of persistent organic pollutants in the aquatic environmentPeer reviewed article
Van Leeuwen, S.P.J.; de Boer, J. (2009). Advances in the gas chromatographic determination of persistent organic pollutants in the aquatic environment J. Chromatogr. 1186(1-2): 161-182
In: Journal of Chromatography A. Elsevier: Amsterdam. ISSN 0021-9673, meer

Beschikbaar in Auteurs 

Trefwoorden
    Aquatisch milieu; Gas chromatography; Organohalogen compounds; Marien; Brak water

Auteurs  Top 

Abstract
    Environmental chemists have been challenged for over 30 years to analyse complex mixtures of halogenated organic pollutants like polychlorinated biphenyls (PCBs), polychlorinated alkanes (PCAs), polybrominated diphenyl ethers (PBDEs) and polychlorinated dibenzo-p-dioxins and polychlorinated furans (PCDD/Fs). Gas chromatography (GC) often proved to be the method of choice because of its high resolution. The recent developments in the field of comprehensive two-dimensional GC (GC × GC) show that this technique can provide much more information than conventional (single-column) GC. Large volume injection (e.g. by programmed temperature vaporiser, or on-column injection) can be employed for the injection of tens of microliters of sample extract, in that way substantially improving the detection limits. Electron-capture detection (ECD) is a sensitive detection method but unambiguous identification is not possible and misidentification easily occurs. Mass spectrometric (MS) detection substantially improves the identification and the better the resolution (as with MS/MS, time-of-flight (TOF) MS and high-resolution (HR)MS), the lower the chances of misidentification are. Unfortunately, this comes only with substantially higher investments and maintenance costs. Co-extracted lipids, sulphur and other interferences can disturb the GC separation and detection leading to unreliable results. Extraction, and more so, sample clean-up and fractionation, are crucial steps prior to the GC analysis of these pollutants. Recent developments in sample extraction and clean-up show that selective pressurised liquid extraction (PLE) is an effective and efficient extraction and clean-up technique that enables processing of multiple samples in less than 1 h. Quality assurance tools such as interlaboratory studies and reference materials are very well established for PCDD/Fs and PCBs but the improvement of that infrastructure is needed for brominated flame retardants, PCAs and toxaphene.

 Top | Auteurs 
 

 

Vlaams Instituut voor de Zee
InnovOcean site
Wandelaarkaai 7
B-8400 OOSTENDE, België
Tel: +32 [0]59/34 21 30
Fax: +32 [0]59/34 21 31
Email: info@vliz.be
   

 

Vlaamse Gemeenschap Provincie West-Vlaanderen