VLIZ
VLAAMS INSTITUUT VOOR DE ZEE
MARIEN EN KUSTGEBONDEN ONDERZOEK & BELEID IN VLAANDEREN
   
© VLIZ © VLIZ © VLIZ © VLIZ © VLIZ
 
 
  English  Sitemap  Print
U bent hier: VLIZ > datacentrum
menu1 Over het VLIZ menu2 Infoloket menu3 Zeebibliotheek menu4 Cijfers&Beleid menu5 Faciliteiten menu6 Datacentrum
   
Datacentrum
  - IMIS: Integrated Marine Information System -
log in

Personen | Instituten | Publicaties | Projecten | Datasets | Kaarten
meld een fout in dit recordmandje (0): toevoegen | tonen Print-vriendelijke versie

Quantification and screening of pesticide residues in food by gas chromatography-exact mass time-of-flight mass spectrometryPeer reviewed article
Leandro, C.C.; Hancock, P.; Fussell, R.J.; Keely, B.J. (2007). Quantification and screening of pesticide residues in food by gas chromatography-exact mass time-of-flight mass spectrometry J. Chromatogr. 1166(1-2): 152-162. hdl.handle.net/10.1016/j.chroma.2007.07.052,
In: Journal of Chromatography A. Elsevier: Amsterdam. ISSN 0021-9673, meer

Trefwoord
    Marien
Author keywords
    Exact mass time-of-flight mass spectrometer; Gas chromatography; Pesticides; Screening

Auteurs  Top 

Abstract
    A gas chromatography–exact mass time-of-flight mass spectrometry (GC–TOF-MS) method has been developed for the quantification of approximately one hundred pesticides in baby food, pear and lettuce samples. Prior to analysis, co-extractives were removed from acetonitrile:toluene (80:20) extracts using dispersive solid-phase extraction with primary secondary amine (50 mg) and carbon sorbent (50 mg). The concentration of pesticides in the extracts was measured using an extracted mass chromatogram window of 0.05 Th. Samples spiked with pesticides at 0.01 and 0.1 mg kg-1 yielded average recoveries in the range of 70–109% with relative standard deviations less than 26% and displayed good linearity for the majority of the analytes. The method was applied to the screening of pear and lettuce samples for pesticide residues. Targeted quantification and exact mass peak detection, deconvolution and library searching packages were used successfully to detect and identify incurred residues present in the samples at concentrations above 0.01 mg kg-1. The new feature dynamic range enhancement, improved mass accuracy, and hence detection and quantification of the analytes across the concentration range studied.

 Top | Auteurs 
 

 

Vlaams Instituut voor de Zee
InnovOcean site
Wandelaarkaai 7
B-8400 OOSTENDE, België
Tel: +32 [0]59/34 21 30
Fax: +32 [0]59/34 21 31
Email: info@vliz.be
   

 

Vlaamse Gemeenschap Provincie West-Vlaanderen