VLIZ
VLAAMS INSTITUUT VOOR DE ZEE
MARIEN EN KUSTGEBONDEN ONDERZOEK & BELEID IN VLAANDEREN
   
© VLIZ © VLIZ © VLIZ © VLIZ © VLIZ
 
 
  English  Sitemap  Print
U bent hier: VLIZ > datacentrum
menu1 Over het VLIZ menu2 Infoloket menu3 Zeebibliotheek menu4 Cijfers&Beleid menu5 Faciliteiten menu6 Datacentrum
   
Datacentrum
  - IMIS: Integrated Marine Information System -
log in

Personen | Instituten | Publicaties | Projecten | Datasets | Kaarten
meld een fout in dit recordmandje (0): toevoegen | tonen Print-vriendelijke versie

The use of high pressure liquid chromatography with fluorimetric detection for chlorophyll A determination in natural extracts of chloropigments and their degradation productsPeer reviewed article
Goeyens, L.; Post, E.; Dehairst, F.; Vandenhoudt, A.; Baeyens, W.F.J. (1982). The use of high pressure liquid chromatography with fluorimetric detection for chlorophyll A determination in natural extracts of chloropigments and their degradation products Int. J. Environ. Anal. Chem. 12: 51-63
In: International journal of environmental and analytical chemistry. Taylor & Francis: London. ISSN 0306-7319, meer

Ook gepubliceerd als
  • Goeyens, L.; Post, E.; Dehairst, F.; Vandenhoudt, A.; Baeyens, W.F.J. (1982). The use of high pressure liquid chromatography with fluorimetric detection for chlorophyll A determination in natural extracts of chloropigments and their degradation products, in: (1982). IZWO Coll. Rep. 12(1982). IZWO Collected Reprints, 12: pp. chapter 15 [Subsequent publication], meer

Beschikbaar in Auteurs 
    VLIZ: Open Repository 128167 [ OMA ]

Trefwoorden
    Chlorofyl; Chromatography; Marien

Auteurs  Top 

Abstract
    To realize chlorophyll A analysis, a method is proposed that combines the sensitivity of fluorimetric determinations and the inherent selectivity and accuracy of chromatographic separations. A partial application of the overlapping resolution mapping (ORM) method led to the use of a methanol:acetone:water (75:22:3, v/v) mixture for the isocratic separation by high pressure liquid chromatography on a reserved phase C-18 column of at least sixteen chloropigments and degradation products in a natural extract. Ten replicate measurements of a 50 µg.l-1 standard showed a reproducibility of 3 promille while a detection limit of 84 pg chlorophyll A was estimated.

 Top | Auteurs 
 

 

Vlaams Instituut voor de Zee
InnovOcean site
Wandelaarkaai 7
B-8400 OOSTENDE, België
Tel: +32 [0]59/34 21 30
Fax: +32 [0]59/34 21 31
Email: info@vliz.be
   

 

Vlaamse Gemeenschap Provincie West-Vlaanderen